Branch Circuit

Branch Circuit

Advanced power protection at the service panel

  • NEMA rated magnetic shielding steel enclosure
  • Advanced Series Mode ® surge elimination technology
  • Impedance Tolerant™ EMI/RFI filtering
  • SurgeX ICE Inrush Current Elimination
  • Self-circuit with visual indicator
  • Remote turn-on (SX-20NE-RT)
  • Self-circuit with visual indicator (SX-20NE-RT)
  • Remote IP control capabilities (SX-20NE-RT-AR)
Download Product Sheet

Have you ever wanted complete surge elimination and power conditioning at the branch circuit level, eliminating the need for additional protection downstream? We have the solution.

The SurgeX Branch Circuit product line provides guaranteed surge elimination and conditioning for audio, video, and mission critical equipment at the service panel. Available in three configurations, our unique solutions are built with professional-grade NEMA magnetic shielding steel enclosures that meet code for use at the service entrance, sub-panels, and in-ceiling plenums.

They are engineered with Advanced Series Mode surge elimination and power conditioning technologies to provide top-of-the-line protection. Superior to conventional MOV circuitry or MOV-hybrid designs, they completely eliminate surge energy up to 6,000 Volts without producing harmful side effects such as ground contamination or common-mode disturbances. Completely non-sacrificial and never needing reset, they provide the most reliable protection available.

Our branch circuit line also features both common mode and normal mode impedance tolerant EMI/RFI filtering, and SurgeX ICE (Inrush Current Elimination) for a complete power conditioning solution.

 

PF-420 SX-20NE-RT  

Load Rating

20 amps per circuit @ 120 volts(80 amps total)

20 amps @ 120 volts

 

Power Requirement (no load)

15 watts per circuit

15 watts per circuit

 

Surge Let- Through Voltage
(6000-volt surge)

1000 surges, 6000 volts, 3000 amps, B3
pulse; Measured suppressed voltage: 170
volts; no failures.

1000 surges, 6000 volts, 3000 amps, B3
pulse; Measured suppressed voltage: 170
volts; no failures.

 

UL 1449 Adjunct Classification Test Results

Grade A, Class 1, Mode 1 (CID A-A-55818)

Grade A, Class 1, Mode 1 (CID A-A-55818)

 

Federal Guidelines

Unlimited, due to current limiting (8 x 20 μs)

Unlimited, due to current limiting (8 x 20 μs)

 

EMI/RFI Filter, Normal Mode
(50-ohm load)

40 dB @ 100 kHz; 50 dB @ 300 kHz;
50 dB @ 3 MHz; 50 dB @ 30 MHz

40 dB @ 100 kHz; 50 dB @ 300 kHz;
50 dB @ 3 MHz; 50 dB @ 30 MHz

 

EMI/RFI Filter, Common Mode
(50-ohm load)

18 dB @ 300 kHz; 30 dB @ 1 MHz;
50 dB @ 5 MHz; 50 dB @ 20 MHz

18 dB @ 300 kHz; 30 dB @ 1 MHz;
50 dB @ 5 MHz; 50 dB @ 20 MHz

 

Maximum Applied
Surge Voltage

6000 volts*

6000 volts*

 

Maximum Applied
Surge Current

Unlimited, due to current limiting*

Unlimited, due to current limiting*

 

Maximum Applied
Surge Energy

Unlimited, due to current limiting*

Unlimited, due to current limiting*

 

Endurance (C62.41-1991 Category B3 pulses)

1 kV>500,000; 3 kV>10,000; 6 kV>1000

1 kV>500,000; 3 kV>10,000; 6 kV>1000

 

Maximum Load Inrush Current During Power-up

N/A

1000 Joules

 

Remote Turn-on Applied
Voltage Range

N/A

Contact Closure: 3 mA
5 V DC Applied Voltage: 1 mA
12 V DC Applied Voltage: 2.5 mA
24 V DC Applied Voltage: 5 mA

 

Auxiliary Relay Contact Rating

N/A

30 Volts at 1 Amp

 

LED Output

12 volts DC, maximum 20 mA (resistor required)

12 volts DC, maximum 20 mA (resistor required)

 

Dimensions

16.0″ H x 12.0″ W x 4.0″ D
(40.6 x 30.5 x 10.2 cm)

12.0″ H x 12.0″ W x 4.0″ D
(30.5 x 30.5 x 10.2 cm)

 

Weight

30 lbs (13.6 kg)

12 lbs (5.45 kg)

 

Temperature Range

5º to 35º C

5º to 35º C

 

Humidity Range

5% to 95% R.H.,
non-condensing

5% to 95% R.H.,
non-condensing

 

Agency Listings

ETL and cETL (UL 1449, 2nd edition;
CSA C22.2 No.8-M1986, R2000)

ETL and cETL (UL 1449, 2nd edition;
CSA C22.2 No.8-M1986, R2000)

 

CE

 

 

 

FCC

 

 

 

NETWORK

 

 

 


*1.2 x 50 μs pulse, industry standard combination wave surge, as per IEEE C62.41

Agency Listings: ETL and cETL (UL 1449, 2nd edition; CSA C22.2 No.8-M1986, R2000)

Specifications subject to change without notice.

PF-420 Install Instructions
Download
SX-20NE-RT-AR
User Manual
SOFTWARE VERSION: 1.01.41
FIRMWARE VERSION: 1.01.06
Download
SX-20NE-RT-AR
Quick Start Guide
Download
SX20-NE/RT Install Instructions
Download
SX20-NE Install Instructions
Download

Axess Ready

DMU
(Device Management Utility)
Current version is 1.30.11
Download
Current Firmware FileCurrent version 1.10.169
Download
DXP Example filesVersion 2.0
Download
Product/Warranty Registration
Register
Warranty
Download