NextGen PCS

Diagnostic intelligence and
industrial-grade power protection

  • Diagnostic software to monitor, diagnose, and manage power issues proactively
  • Industrial-grade power protection technology
  • Safeguards equipment from surges, spikes, catastrophic over/under voltage, EMI/RFI noise and wiring faults
  • Cat5e ETL and telephone line protection
  • Power over Ethernet protection
  • Remote IP capable (sold separately)
  • Lifetime product and connected equipment protection warranty
Brochure

Watch Product Video

 

 

Features

The Next Gen PCS provides advanced electrical troubleshooting and power protection technology to help service teams monitor live electrical incidents, troubleshoot downtime, reduce service costs, and equipment/part replacement costs It offers service teams the ability to pre-diagnose power issues proactively to better understand, prevent, and react to them before disruption, damage, downtime, and lost income is incurred. Its innovative microprocessor is the only product in the industry that records time-stamped power anomalies and enables power protection settings to be customized instantaneously.

This comprehensive solution also includes industrial-grade Multi-Stage protection to safeguard equipment from the dangers associated with damaging surges, spikes, over/under voltage, EMI/RFI noise and wiring faults.

 

Model
Plug Configuration
Description
Input
Output
XG-PCS-15D
NEMA-5-15PNEMA 5-15P
NEMA-6-15R(3x) NEMA 5-15R
ESP Next Gen PCS Diagnostic Power Filter,
Diagnostic Software included, 120V/15A, 1 Pigtail + 2 Receptacles, Networked
XG-PCS-20D
NEMA-5-20PNEMA 5-20P
NEMA-5-20R(1x) NEMA 5-20R
NEMA-5-20R(2x) NEMA 5-15R
ESP Next Gen PCS Diagnostic Power Filter,
Diagnostic Software included, 120V/20A, 1 Pigtail + 2 Receptacles, Networked
XG-PCS-20815D
NEMA-6-15PNEMA 6-15P
NEMA-6-15R(1x) NEMA 6-15R
ESP Next Gen PCS Diagnostic Power Filter,
Diagnostic Software included, 208V/15A, 1 Pigtail, Networked
XG-PCS-20820D
NEMA-6-20PNEMA 6-20P
NEMA-6-20R(1x) NEMA 6-20R
ESP Next Gen PCS Diagnostic Power Filter,
Diagnostic Software included, 208V/20A, 1 Pigtail, Networked
XG-PCS-L630
NEMA-L-630PNEMA L6-30P
NEMA-L-630R.png(1x) NEMA L6-30R

ESP Next Gen PCS Diagnostic Power Filter,
Diagnostic Software included, 240V/30A, Networked
XG-PCS-L630-GNS
NEMA-L-630PNEMA L6-30P
NEMA-L-630R.png(1x) NEMA L6-30R

ESP Next Gen PCS Diagnostic Power Filter with Gigabit Network Switch,
Diagnostic Software included, 240V/30A, Networked
XG-PCS-IC-1Next Gen PCS Interface Cord, 1 Cord

Models: XG-PCS-15D, XG-PCS-20D, XG-PCS-20815D, XG-PCS-20820D, XG-PCS-23014, XG-PCS-L631, XG-PCS-631

Specifications

15/20 Amp Models

XG-PCS-15D (120 Volt, 15 Amp)
XG-PCS-20D (120 Volt, 20 Amp)
XG-PCS-20815D (208 Volt, 15 Amp)
XG-PCS-20820D (208 Volt, 20 Amp)
XG-PCS-IC-1 (Interface Cord, 1 Cord – Sold Separately)
XG-PCS-IC-10 (Interface Cord Bundle, 10 Cords – Sold Separately)

Physical

Dimensions: 6.125” W x 8.375” D x 2” H
Weight: 2.4 lb. (XG-PCS-15D / XG-PCS-20D), 2.6 lb. (XG-PCS-20815D / XG-PCS-20820D)
Temperature Range: 5C to 35C
Humidity Range: 5% to 95% R.H. Non-condensing

Electrical

Load Rating: 15/20 Amps at 120 Volts (XG-PCS-15D / XG-PCS-20D), 15/20 Amps at 120/230 Volts Split Phase (XG-PCS-20815D / XG-PCS-20820D)
Voltage Protection Rating (VPR): 330V All Modes (XG-PCS-15D / XG-PCS-20D), 500V L-G, 800V L-L (XG-PCS-20815D / XG-PCS-20820D)
Attenuation:
– Normal Mode: >30dB 80kHz – 50MHz
– Common Mode: >30dB 70kHz – 50MHz (XG-PCS-15D / XG-PCS-20D),
>30dB 200kHz – 50MHz (XG-PCS-20815D / XG-PCS-20820D)
Power Requirement (no load): 4 Watts
Under-Voltage Shutdown: Adjustable from 80 Volts to 95 Volts, or Disabled.
– Restores at 105 Volts. (XG-PCS-15D / XG-PCS-20D) Adjustable from 140 Volts to 170 Volts, or Disabled.
– Restores at 190 Volts. (XG-PCS-20815D / XG-PCS-20820D)
Over-Voltage Shutdown: Adjustable from 135 Volts to 160 Volts.
– Restores at 130 Volts. (XG-PCS-15D / XG-PCS-20D) Adjustable from 260 Volts to 300 Volts.
– Restores at 250 Volts. (XG-PCS-20815D / XG-PCS-20820D)
Internal Memory Capacity: 60 Events with timestamp; 999 counts of each event type
Voltmeter Accuracy: Peak reading type. Typical product accuracy is ±2% between:
40V and 180V: (XG-PCS-15D / XG-PCS-20D)
100V and 300V: (XG-PCS-20815D / XG-PCS-20820D)
Timestamp accuracy: ±2.5%
Response Time: 100msec Over-Voltage / 150msec Under-Voltage
Under-Voltage Record Event Definition: AC voltage has dropped below:
100V (XG-PCS-15D / XG-PCS-20D)
180V (XG-PCS-20815D / XG-PCS-20820D)
Over-Voltage Record Event Definition: AC voltage has risen above:
135V (XG-PCS-15D / XG-PCS-20D)
260V (XG-PCS-20815D / XG-PCS-20820D)
Power Outage Event Definition: AC voltage has dropped below 20V.
Surge Event Definition: Next Gen PCS Filter has been exposed to a transient voltage in one of the 3 possible modes (between Live and Neutral, between Live and Ground, between Neutral and Ground) with a peak amplitude of 500V* (XG-PCS-15D / XG-PCS-20D); 700V* (XG-PCS-20815D / XG-PCS-20820D) or higher and a frequency of 20 kHz or higher. *500V/700V surge voltage amplitude applies to IEEE C62.41 Category B Impulse; surge voltage amplitudes necessary for detection of other surge types may vary.
Modem/Fax Protection: Single telephone line surge suppression.
Ethernet Protection: Cat5e network surge protection, ETL Certified to TIA/EIA-568-B.2.
Computer Requirements

PC Requirements: For use with Next Gen PCS Diagnostic Software. Minimum 133MHz Pentium processor (or equivalent), minimum 64MB of RAM, minimum 10MB free hard drive space, VGA or higher resolution monitor, keyboard, mouse, CD or DVD drive, minimum screen resolution of 1024×768, Microsoft Windows 2000/XP/Vista/7.
Standards Compliance

Agency Listings: ETL Certified to UL 1449 (3rd Edition), ETL Certified to TIA/EIA-568-B.2 Cat 5e, Industry Canada Certified
** Specifications subject to change without notice
** All listed specifications obtained at an ambient temperature of 25°C

30 Amp Models

XG-PCS-L630 (208 Volt, 30 Amp)
XG-PCS-630 (208 Volt, 30 Amp)
XG-PCS-IC-1 (Interface Cord, 1 Cord – Sold Separately)
XG-PCS-IC-10 (Interface Cord Bundle, 10 Cords – Sold Separately)
Physical

Dimensions: 7.75” W x 4.5” D x 11.25” H
Weight: 10 lb.
Temperature Range: 5C to 35C
Humidity Range: 5% to 95% R.H. Non-condensing
Electrical

Load Rating: 30 Amps at 120/230 Volts, Split Phase
Voltage Protection Rating (VPR): 500V L-G, 800V L-L
Attenuation:
– Normal Mode: >30dB 80kHz – 50MHz
– Common Mode: >30dB 200kHz – 50MHz
Power Requirement (no load): 4 Watts
Under-Voltage Shutdown:
– Adjustable from 140 Volts to 170 Volts, or Disabled.
– Restores at 190 Volts.
Over-Voltage Shutdown:
– Adjustable from 260Volts to 300 Volts.
– Restores at 250 Volts.
Internal Memory Capacity: 60 Events with timestamp; 999 counts of each event type
Voltmeter Accuracy: Peak reading type. Typical product accuracy is ±2% between:
100V and 300V
Timestamp accuracy: ±2.5%
Response Time: 100msec Over-Voltage / 150msec Under-Voltage
Under-Voltage Record Event Definition: AC voltage has dropped below: 180V
Over-Voltage Record Event Definition: AC voltage has risen above: 260V
Power Outage Event Definition: AC voltage has dropped below 20V.
Surge Event Definition: Next Gen PCS Filter has been exposed to a transient voltage in one of the 3 possible modes (between Live and Neutral, between Live and Ground, between Neutral and Ground) with a peak amplitude of 700Volts* or higher and a frequency of 20 kHz or higher.
*700V surge voltage amplitude applies to IEEE C62.41 Category B Impulse; surge voltage amplitudes necessary for detection of other surge types may vary.
Modem/Fax Protection: Single telephone line surge suppression.
Ethernet Protection: Cat5e network surge protection, ETL Certified to TIA/EIA-568-B.2.
Computer Requirements

PC Requirements: For use with Next Gen PCS Diagnostic Software. Minimum 133MHz Pentium processor (or equivalent), minimum 64MB of RAM, minimum 10MB free hard drive space, VGA or higher resolution monitor, keyboard, mouse, CD or DVD drive, minimum screen resolution of 1024×768, Microsoft Windows 2000/XP/Vista/7.
Standards Compliance

Agency Listings: ETL Certification to UL 1449 (3rd Edition) – in process, ETL Certified to TIA/EIA-568-B.2 Cat 5e, Industry Canada Certified
** Specifications subject to change without notice
** All listed specifications obtained at an ambient temperature of 25°C

Downloads

User Manual
Download
Software
Download

ESP Lifetime Warranty

This product includes a limited lifetime product and a connected equipment protection warranty. A protection guarantee that provides you with peace of mind that you’re covered for power related “Acts of God”- for life!

We offer the most comprehensive guarantee in the industry because our products provide the most advanced protection available. We guarantee the product will be free from defects in material and workmanship from the date of original purchase and for as long as you are the original owner. In the event there are defects in the material and/or workmanship of your ESP product we will either repair or replace the product at no charge.

Now that’s true power protection!

Download Warranty